Your reliable Laboratory Instruments specialist

Your reliable Laboratory Instruments specialist

Fluorescence Spectrophotometer, BNFLU-A96

Emission monochromator: C-T diffraction grating
Emission wavelength: 200~650nm
Emission bandwidth: 10nm
Wavelength accuracy: ±1nm
Wavelength repeatability: ≤0.5nm


 

Excitation light source High brightness LED
Excitation LED 250nm ~ 600nm(LED)
EX wavelength standard set: 365nm,376nm,392nm,405nm
Emission monochromator C-T configuration diffraction grating monochromator
Emission wavelength range (EM): 200nm ~ 650nm,
Bandwidth: 10nm
(Extend the monochromator to Em200-900 is optional.)
Emission wavelength accuracy ± 1nm
Emission wavelength reproducibility ≤ 0.5nm
S∕N ratio S/N≥90(Using 1cm quartz sample cell, measure the signal
noise ratio of Raman spectrum of water )
Detection limit 1 × 10-10 g / ml quinine sulfate solution
Linearity (γ) ≥0.995
Repetitive peak intensity ≤1.5%
Zero drift ≤0.3(within 10min)
Upper limit change of indicating value ≤1.5% (Within 10 minutes) (displaying value≥50)
Power supply AC 220V 50Hz / 110V 60Hz, 35W
Dimensions 442×392×250mm
Net Weight 10kg
Gross Weight 12kg
Two mode could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic determination and quantity analysis could be done under fluorescence intensity mode.
365nm exciting wavelength Raman peak of water in 1 cm quartz fluorescence cuvette S/N≥150 High performance sensitivity simplifies the measurement of low detective sample.
10 stages gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N scanning and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre scanning feature, unknown sample's spectrum information could be detected rapidly. Auto-omission of the influence of scattering peak and harmonic peaks, it ensure the best measurement parameters and locate the fluorescence emission peak.
Support off-line mode and on-line mode. Under off-line mode, instrument's computer system offer the fluorescence intensity measurement, concentration direct reading, auto 0 adjustment, auto background subtraction and etc. Under on-line mode, we could use quality and quantity software to control data acquisition and analysis through USB2.0 interface.
High stable and long life 150W xenon lamp and power source ensure high stable testing and wide range of spectrum.
The normalized feature for fluorescence value could make different fluorescence's result comparable.
Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning, graphic calculation and storage-access abilities.
Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder for different features, 200µl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories, jacket sample accessories and etc.
 