Technical data:
Wavelength range 190 – 900nm
Spectral bandwidth 0.1, 0.2, 0.4, 1.0 and 2.0nm
Accuracy of the wavelength ±0.15nm
Receptivity of the wavelength ≤0.04nm
Base line stability ≤0.002A/30min (Cu)
Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
Preciseness 0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand 8
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight 700mm×550mm×450mm  75Kg
Power source 220V±22V  AC

Flame system
Acetylene air burner 100mm
Ignition dynamic baseline drift ≤0.006A/30min
(Cu) Characteristic viscosity ≤0.025μg/ml/1%
Related standard deviation of the accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety system Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite furnace
The highest temperature 3000℃
The largest temperature rising speed ≥2000℃/S
Characteristic quantity   Cd≤0.5×10-12g  Cu≤0.5×10-11g
Accuracy Cu≤3%   Cd≤3%
Size and weight 550mm×450mm×300mm  65Kg
Safety system Over current protection
Low air pressure alarm / protection
Low cooling water flow alarm/protection
Power source and power 220V±22V   AC   7000W
Standard Accessories
PC workstation
HP inkjet printer
Oil free Air compressor 
Acetylene reducing valve
Cu Hollow cathode lamp
Air filter


Optional accessories
Hollow cathode lamp
Graphite tubes
Recirculating cooling water system
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background regulation
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flame absorption method and emission method.
10. Result printing: parameter printing, data result printing and diagram printing.
Complete automatic controlling system 
With the help of the software, the following can be easily achieved
1.Selection of the element lamp
2.Up-down-front-rear adjustment of the lifter
3.Adjustment of the optical energy
4.Selection of the slit
5.Determination of wavelength scanning and peak searching
6.Selection of the atomizer
7.Setting of the background deduction method 
8.Controlling of the gas flow
9.Automatic flaming and flaming out 
10.Setting of the graphite furnace testing method 


Advanced graphite furnace temperature controlling technology
1.The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data
2.The fast heating capacity can improve the flexibility of the elements further 
3.Use the ordinary power source of 220V without need of dynamic power of 380V
4.The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
5.Three grades adjustable gas flow can accustom to more application needs  
6.Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error

 
No PDF document available for this product at present

Leave a message

Please fill in information, we will get back to you within 24 hours.

Related Products

Add: Rm.1101,Building 1,No.1428 Huanding Rd,Jianggan Dist.,Hangzhou 310021,China
Fax: +86-571-85383683