Flame Graphite Furnace Atomic Absorption Spectrophotometer, BNAAS-C130G

Wavelength range: 190nm-900nm
Wavelength accuracy: ±0.25nm
Baseline stability: ≤0.004A/30min

Technical Data:
Main Specification Wavelength range 190-900n
Wavelength accuracy ±0.25nm
Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability ≤0.004A/30min
Background correction The D2 lamp background correction capability at 1A is better than 30 times.  
Hollow Cathode Lamps Lamp turret 4-lamp turret
Auto-alignment, fully automated scan and peak-picking.
Lamp current adjustment Automatic adjustment and display.           Wide pulse current: 0~25mA,              Narrow pulse current: 0~10mA                  
Lamp power supply mode 400Hz square wave pulse
Optical System Monochomator Single beam, Czerny-Turner design grating monochromator
Grating 1800 l/mm
Focal length 277mm
Blazed Wavelength 250nm
Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change.
Flame Atomizer Burner 10cm single slot all-titanium burner    
Spray chamber Corrosion resistant all-plastic spray chamber.
Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min
Graphite Furnace Temperature range Room temperature~3000ºC
Heating rate  2000℃/s
Graphite tube dimensions 28mm (L) x 8mm (OD)
Characteristic mass Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
Precision Cd≤3%, Cu≤3%, Mo≤4%
Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range.
Software Windows operating system
Analytical method Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content.
Repeat times Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task function Sequential measurement of multi-elements in one sample
Condition reading With model function
Result printing Measurement data and final analytical report printout, editing with Excel.
Standard RS-232 serial port communication
Characteristic Concentration and Detection Limit Normal Air-C2H2 flame Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Oxygen-rich Air-C2H2 flame Ba:  Characteristic concentration ≤ 0.22mg/L
Function Expansion Hydride vapor generator can be connected for hydride analysis.
Dimensions and weight 1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg
420 (L) × 420 (W) × 460 (H) mm (graphite furnace), unpacked 50kg
Integrated flflame/graphite furnace atomization system, changeable with flflame emission burner
Automatically controlled changeover of the integrated flflame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor.
A flflame emission burner head can be installed to perform flflame emission analysis to Alkali metals as K, Na etc. (BNAAS-C110G/C120G)

Easy and practical analysis software
Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
Automatic display of measured data, automatic calculation and analytical result automatic print out.

Accurate fully automated control system
Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position.
Automatic wavelength scanning and peak picking
Automatic spectral bandwidth changing
Automatic changeover between flflame and graphite furnace operation, automatic optimization of position parameters, and automatic ignition 
 
Accurate fully automated control system
Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%.
Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

Perfect safety protection measures
Alarm and automatic protection to fuel gas leakage, abnormal flflow, insufficient air pressure and abnormal flflame extinction in flflame system;
Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling water supply and over-heating in graphite furnace system.

Advanced and reliable electronic design
Adopting large-scale programmable logic array and Inter I2C bus technology
European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.
Atomic absorption spectrophotometer is used to analyze elements in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industries.